Air in a closed system isn't necessarily a disaster - it's actually pretty normal when you're first starting up. Water contains dissolved oxygen, and when the system fills and heats up, the air starts releasing. Plus there's always some air left behind when you install the pipes and radiators.
You need to get rid of it gradually and properly. First, make sure the pressure in the membrane expansion tank is correct - it should be roughly 0.2 atm lower than your system's working pressure (usually 1-1.5 atm). Then turn on the circulation pump and let the system run for a couple of hours - the air will start collecting at the high points and in the radiators themselves. Now slowly open the Mayevsky valves on the radiators, starting from the upper floors. Air will come out of the valve first (you'll hear a thin hissing sound), then water will appear. Open it just a tiny bit, not all the way, or you might actually let too much extra air out. If your system has an automatic air vent, it'll handle most of the problem on its own, but the manual valves will still help you get rid of any remaining air pockets.