When the pilot lights but the main flame won't ignite, nine times out of ten it's the thermocouple or a stuck solenoid valve. Since you've cleaned the burner, the next step is to check if the thermocouple is actually making contact with the pilot flame - sometimes it shifts slightly over time and the valve doesn't get the signal. Try moving it carefully, making sure it sits right under the flame.
If that's not it, the valve itself might be clogged with limescale deposits (especially if you have hard water). The trick nobody mentions is to turn everything off, wait 20 minutes, then turn it back on several times in a row - sometimes that forces the internal mechanism to come loose. If you're still out of luck, that solenoid valve probably needs to be replaced. At 15 years of use, some wear is normal; you don't need to swap out the whole heater, but that part has a limited lifespan.